bt-q1000x

Flow's picture

BT-Q1000X mit Point-of-Interests Button

Hi,

ich bin auf der Suche nach einen Logger mit POI Button, also einen Knopf der die aktuelle Postion im Log besonders speichert. Mit dem MTK2 Chipsatz konnte ich nur den BT-Q1000X finden.

Kann bt747 die POI Button Daten aus den Log auslesen und evtl in einen gesonderten Track (bzw. File) exportieren?

Flow

BT-Q1000X quirks

It looks like Qstarz is going a similar way as Holux is: limiting device functionality for user friendlyness. This is not to the likings of some users of course, but to warn those, here is a list of limitations.  If you find any other, or some incorrect statement, leave a comment.

  1. Time logging can not be set to 5Hz.  When setting logging to 0.2 seconds, logging is set to 5 seconds.  (This is what is reported, but I'ld like to see it confirmed by transaction logs).  The Fix Period has to be set to 200ms if this is meant to work anyway.
  2. 5Hz logging can still be achieved by setting the fix period to 200ms and the speed condition to a minimum value like 1 km/h.  The distance condition possibly also works here.
  3. Logging can not really be turned on/off by SW.  The 'nav/log/off' button of the logger is the master of this.  Technically, the device does respond correctly to instructions from the SW (BT747) to turn logging on and off, but the firmware checks/sets that value to the one that corresponds to the button position.  In nav mode, logging is set to off, and in log mode, logging is set to on.

That seems to be it, but as said, you can add comments to this post.